Accusys 8074bee4a1 docs: M4ProMini worker offline root cause analysis
- Identified plist hardcoded paths as root cause
- v1.3.2 code improvements insufficient (plist not modified)
- Added fix script: scripts/fix_m4promini_plist.sh
- Proposed v1.3.3 solution: plist templates